4. Check the Auto Enumerating COM Name check-box to assign continuous COM
numbers for subsequent ports. For example, if COM3 is assigned to Port 1, then COM4
will be automatically assigned to Port 2.
5. Re-assign the Rx FIFO Trigger by selecting a number from the pull-down list. Check
the Set the change to all ports check-box to apply this setting to all ports. Rx FIFO
trigger levels from 1 to 62 bytes are available, with a default value of 56 bytes.
6. Re-assign the Tx FIFO Size by selecting a number from the pull-down list. Check the
Set the change to all ports check-box to apply this setting to all ports. Tx FIFO sizes
from 1 to 64 bytes are available, with a default value of 64 bytes.
7. To complete the update, click [OK] in the Port X dialog box, click [OK] in the CP-
168U board Properties dialog box, and then click [OK] on the Device Manager tab.
8. Restart the system to activate the latest configuration.
Updating the Driver
This section shows how to update the Windows 95/98 driver.
Smartio CP-168U User’s Manual
3-18