Moxa Technologies INTELLIO C218 Manual de usuario Pagina 109

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 122
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 108
Troubleshooting
Intellio C320Turbo User's Manual 6-7
Windows 95/98
This section is specific for troubleshooting under Windows 95/98. For general
problems and solutions, please see the previous section, General Troubleshooting.
1. Error message C320Turbo at base memory [XXX] download failure! appears.
Shutdown the system first and refer to the problem 3 for solutions in the previous
section, General Troubleshooting.
2. Error message C320Turbo at base memory [XXX] number of UART Modules
mismatch! appears.
Make sure that all the module(s) is(are) fastened properly. Or click on the Taskbar
[Start] button, [Programs] menu, [MOXA Utilities] menu, [MOXA Configuration
Panel] icon, and connect the CPU Module with proper number of UART
Module(s) as configured.
3. Error message C320Turbo at base memory [XXX] ports number mismatch!
appears.
Make sure that all the Module(s) is(are) fastened properly and the ports installed
are the same as configured. Or click on the Taskbar [Start] button, [Programs]
menu, [MOXA Utilities] menu and [MOXA Configuration Panel] icon, and
connect the Basic Module with proper number of Extensive Module(s) as
configured.
4. Error message C320Turbo at base memory [XXX] CPU/Basic Module not
found! appears.
Shutdown the system first and refer to the problem 3 for solutions in the
previous section, General Troubleshooting.
5. Error message 320Turbo at base memory [XXX] CPU/Basic Module download
failure! appears.
Shutdown the system first and refer to the problem 3 for solutions in the
previous section, General Troubleshooting.
6. Error message C320Turbo at base memory [XXX] interrupt failure! appears.
Vista de pagina 108
1 2 ... 104 105 106 107 108 109 110 111 112 113 114 ... 121 122

Comentarios a estos manuales

Sin comentarios