Managed Ethernet Switch Solutions
1-22
EDS-508A/505A Series
1
Managed Ethernet Switch
The EDS-508A/505A series is easily configured over the
network by web browser, Telnet console, or a Moxa provided
Windows utility. In addition, Moxa’s Batch Configurator can
also be used to store and copy configuration parameters to
multiple EDS-508A/505A units simultaneously.
Dimensions (unit = mm)
Side View Front ViewDIN-Rail Kit Rear View Panel Mounting Kit
Specications
Technology
Standards: IEEE802.3, 802.3u, 802.3x, 802.1D, 802.1W,
802.1Q, 802.1p , 802.1X, 802.3ad
Protocols: IGMP V1/V2/V3 device, GVRP, SNMP V1/V2c/
V3, DHCP Server/Client, BootP, TFTP, SNTP, SMTP, RARP,
GMRP, LACP, RMON and EDS-SNMP OPC Server Pro (Optional)
MIB: MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE
MIB, Bridge MIB, RSTP MIB, RMON Group 1, 2, 3, 9
Flow Control: IEEE802.3x flow control, back pressure flow control
Interface
RJ45 Ports: 10/100BaseT(X) auto negotiation speed, F/H
duplex mode, and auto MDI/MDI-X connection
Fiber Ports: 100BaseFX ports (SC/ ST connector)
Console: RS-232 (RJ45)
LED Indicators:
PWR1, PWR2, FAULT, MASTER, COUPLER, 10/100M
DIP Switch: Turbo Ring, Master, Coupler, Reserve
Alarm Contact: Two relay outputs with current carrying
capacity of 1A @ 24 VDC
Digital Input: Two inputs with the same ground, but
electrically isolated from the electronics.
• +13 to +30V for state “1”
• -30 to +3V for state “0”
• Max. input current: 8 mA
Optical Fiber
Distance:
Multi mode: 0 to 5 km, 1300 nm (50/125 µm, 800 MHz*km)
0 to 4 km, 1300 nm (62.5/125 µm, 500 MHz*km)
Single mode:
0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km))
0 to 80 km, 1550 nm (9/125 µm, 19 PS/(nm*km))
Multi mode :
-20 dBm
Single mode: 0 to 40 km, -5 dBm
0 to 80 km, -5 dBm
Max. TX Output:
Multi mode : -14 dBm
Single mode:
0 to 40 km, 0 dBm
0 to 80 km, 0 dBm
Sensitivity: -36 to -32 dBm (Single), -34 to -30 dBm (Multi)