Industrial Ethernet Solutions for
Control and Automation
e-mail: info@moxanet.com www.moxa.com
Optical Fiber
Distance:
Multi mode: 0 to 5 km, 1310 nm (50/125 µm, 800 MHz*km)
0 to 4 km, 1310 nm (62.5/125 µm, 500 MHz*km)
Single mode: 0 to 15 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km))
0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/(nm*km))
0 to 80 km, 1550 nm (9/125 µm, 19 PS/(nm*km))
Min. TX Output:
Multi mode : -20 dBm
Single mode: 0 to 15 km, -15 dBm
0 to 40 km, -5 dBm
0 to 80 km, -5 dBm
Max. TX Output:
Multi mode : -14 dBm
Single mode: 0 to 15 km, -6 dBm
0 to 40 km, 0 dBm
0 to 80 km, 0 dBm
Sensitivity: -36 to -32 dBm (Single), -34 to -30 dBm (Multi)
Power
Input Voltage: 24 VDC (12 to 48 VDC), redundant dual inputs
Input Current (@24V): 0.29A: (EDS-508),
0.43A: (EDS-508-MM-SC, EDS-508-SS-SC)
Connection: Two removable 6-pin terminal blocks
Overload Current Protection: Present, can withstand 1.6A
Reverse Polarity Protection: Present
Mechanical
Casing: IP30 protection, aluminum case
Dimensions: 80.5 x 135 x 105 mm (W x H x D)
Weight: 1.04 kg
EDS-508: Industrial Redundant Ethernet Switch with 8 10/100BaseT(X) ports, Operating Temp. 0 to 60°C
EDS-508-MM-SC: Industrial Redundant Ethernet Switch with 6 10/100BaseT(X) ports, 2 multi mode 100BaseFX ports,
Operating Temp. 0 to 60°C
EDS-508-SS-SC: Industrial Redundant Ethernet Switch with 6 10/100BaseT(X) ports, 2 single mode 100BaseFX ports,
Operating Temp. 0 to 60°C
Extended Operating Temperature Models (-40 to 75°C):
EDS-508-T: Industrial Redundant Ethernet Switch with 8 10/100BaseT(X) ports, Operating Temp. -40 to 75°C
EDS-508-MM-SC-T: Industrial Redundant Ethernet Switch with 6 10/100BaseT(X) ports, 2 multi mode 100BaseFX ports,
Operating Temp. -40 to 75°C
EDS-508-SS-SC-T: Industrial Redundant Ethernet Switch with 6 10/100BaseT(X) ports, 2 single mode 100BaseFX ports,
Operating Temp. -40 to 75°C
,ONGHAULTRANSMITFOR3INGLEMODEOPTICALlBEROFKMANDKMAREALSOAVAILABLE
Optional Accessories
DR-4524: 45W/2A DIN-Rail 24 VDC Power Supply with universal 85 to 264 VAC input
DR-75-24: 75W/3.2A DIN-Rail 24 VDC Power Supply with universal 85 to 264 VAC input
DR-120-24: 120W/5A DIN-Rail 24 VDC Power Supply with 88 to 132 VAC/176 to 264 VAC input by switch
*See page 9-5 for more details about these DIN-Rail Power Supplies.
EDS-SNMP OPC Server Pro: CD with EDS-SNMP OPC Server Software and Manual
WK-46: Wall Mounting Kit
Ordering information
Installation: DIN-Rail, Wall Mounting (optional kit)
Environmental
Operating Temperature:
0 to 60°C (32 to 140°F)
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5% to 95% (non-condensing)
Regulatory Approvals
Safety: UL60950 (E212360), UL 508, CSA C22.2 No. 60950,
EN60950
Hazardous location:
UL/cUL Class I, Division 2,
Groups A, B, C and D (E238559)
ATEX Class I, Zone 2, EEx nC IIC (03CA24537)
EMI: FCC Part 15, CISPR (EN55022) class A,
EMS: EN61000-4-2 (ESD), level 3
EN61000-4-3 (RS), level 3
EN61000-4-4 (EFT), level 4
EN61000-4-5 (Surge), level 3
EN61000-4-6 (CS), level 3
EN61000-4-8
EN61000-4-11
EN61000-4-12
Shock: IEC60068-2-27
Free Fall: IEC60068-2-32
Vibration: IEC60068-2-6
MTBF: 260,000 hours
Data Base: MIL-HDBK-217F, GB
WARRANTY: 5 years
1-17