EDS-516A Series User’s Manual Featured Functions
3-44
Port Type
Setting Description Factory Default
Access This port type is used to connect single devices without
tags.
Trunk Select “Trunk” port type to connect another 802.1Q
VLAN aware switch or another LAN that combines
tagged and/or untagged devices and/or other
switches/hubs.
Access
ATTENTION
For communication redundancy in the VLAN environment, set “Redundant Port,” “Coupling
Port,” and “Coupling Control Port” as “Trunk Port,” since these ports act as the “backbone” to
transmit all packets of different VLANs to different EDS-516A units.
Port PVID
Setting Description Factory Default
VID range from 1
to 4094
Set the port default VLAN ID for untagged devices that
connect to the port.
1
Fixed VLAN List (Tagged)
Setting Description Factory Default
VID range from 1
to 4094
This field will be active only when selecting the “Trunk
port type. Set the other VLAN ID for tagged devices that
connect to the “Trunk” port. Use commas to separate
different VIDs.
None
Forbidden VLAN List
Setting Description Factory Default
VID range from 1
to 4094
This field will be active only when selecting the “Trunk
port type. Set the VLAN IDs that will not be supported
by this trunk port. Use commas to separate different
VIDs.
None