UC-8410/8416/8418/8430 Hardware Introduction
10-pin screw terminal block (4 points, COM, GND)
3 KV optical isolation
sink type
-8410/8416/UC8430: 4 channels
-8418: 12 channels
Output Current: Max. 200 mA per channel
-state Voltage: 24 VDC nominal, open collector to 30 V
10-pin screw terminal block (4 points, GND)
3 KV optical isolation
CANbus Communication (UC-8418 only)
Dual optically isolated CAN2.0A/2.0B compliant ports
Phillips SJA1000T
CAN-H, CAN-L
2 KV digital isolation
10 Kbps to 1 Mbps
DB9 male
Power, Ready, Storage, Battery for SRAM
10M/Link x 2, 100M/Link x 2 (on connector)
TxD x 8, RxD x 8
Supports "Reset to Factory Default"
SECC sheet metal (1 mm)
1 kg
-8410: 200 x 37 x 120 mm (7.87 x 1.46 x 4.72 in)
-8416/8418: 200 x 57 x 120 mm (7.87 x 2.24 x 4.72 in)
DIN-Rail, wall
-10 to 60°C (14 to 140°F)
-40 to 75°C (-40 to 167°F)
5 to 95% RH
-20 to 75°C (-4 to 167°F)
Temp. Models: -40 to 85°C (-40 to 185°F)
-vibration: 2 g rms @ IEC-68-2-34, random wave, 5-500 Hz, 1 hr per axis
-shock: 20 g @ IEC-68-2-27, half sine wave, 11 ms
12 to 48 VDC (3-pin terminal block)
Consumption: 15 W
CE (EN55022 Class B, EN55024-4-2, EN55024-4-3,
-4-4), FCC (Part 15 Subpart B, Class B)
UL/cUL (UL60950-1), CCC (GB9254, GB 17625.1), LVD (EN60950)
Built-in buzzer and RTC (real-time clock)
Automatic Reboot Trigger:
Built-in WDT (watchdog timer)