3-12
www.moxa.com
Ethernet Media Converters and Extenders
Ethernet Media Converters and Extenders >
3
PTC-101 Series
Panel Mounting Kit (Optional)
Rear ViewFront ViewSide View
PTC-101-M-ST-HV (other models available by request)
Dimensions
Unit: mm (inch)
Environmental Type Tests
Test Description Test Levels
IEC 60068-2-1
Cold, operating (power ON/OFF) Test Ad -40°C, 48 hours
IEC 60068-2-3
Damp heat, steady state, operating Test Ca 85°C, 95% R.H., 24 hours
IEC 60068-2-14
Changing temperature, operating Test Nb -40 to 85°C, Ramp rate: 3°C/min, 8 cycles
IEC 60068-2-48
IEC 60068-2-1
Cold, storage Test Ad -40°C, 12 hours
IEC 60068-2-48
IEC 60068-2-3
Damp heat, steady state, storage Test Ca 90°C, 95% R.H., 24 hours
IEC 60068-2-32
ISTA-2A
Freefall, package Test Ed 90 cm
IEC 60068-2-34
Random vibration, package Test Fd 3 grms (5 to 500 Hz)
IEC 61850-3
IEC 60870-2-2
IEC 60068-2-6
IEC 60721-3-3
Vibration, operating Class Cm (3M6, 4M6)
20 m/s² (9 to 200 Hz)
15 m/s² (200 to 500 Hz)
IEC 61850-3
IEC 60870-2-2
IEC 60068-2-27
IEC 60721-3-3
Shock, operating Class Cm (3M6, 4M6) 300 m/s², 11 ms
Power Requirements
Input Voltage:
Power Supply Type Power Consumption Fuse Rating
LV - DC
20 to 72 VDC 170 mA @ 20 VDC 3.15A(T) 2
HV - AC
85 to 264 VAC 73 mA @ 85 VAC 3.15A(T) 2
HV - DC
88 to 300 VDC 47 mA @ 88 VDC 3.15A(T) 2
LV-DC compliant with EN 50155 on 48VDC
HV-DC compliant with EN 50155 on 110VDC
Connection: Removable terminal block
Overload Current Protection: 1.6 A (protects against two signals
shorted together)
Reverse Polarity Protection: Protects against V+/V- reversal
Standards and Certifications
Safety: UL 60950-1
EMC: CE, FCC
EMI: FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS:
EN 61000-4-2 (ESD) Level 4,
EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 4,
EN 61000-4-5 (Surge) Level 4,
EN 61000-4-6 (CS) Level 3,
EN 61000-4-8 (PFMF) Level 5,
EN 61000-4-11
Power Automation: IEC 61850-3, IEEE 1613
Rail Traffic: EN 50155, EN 50121-4
Freefall: IEC 60068-2-32
Vibration: IEC-61850-3, IEC-60870-2-2, EN 50125-3 (M12 models only)
Green Product: RoHS, CRoHS, WEEE
Note: Refer to the “Environmental Type Tests” table below for more detailed
information.
MTBF (mean time between failures)
Time: 1,211,613 hrs
Database: Telcordia (Bellcore), GB
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
144.15 (5.68)
8 (0.31)
67.4 (2.65)
15
(0.59)
19 (0.75)
26.2
(1.03)
26.06
(1.03)
30.5 (1.2)
34 (1.34)
51.6 (2.03)
54 (2.13)
67 (2.64)
101.4 (3.99)
111.4 (4.39)
123.46 (4.86)
135.1 (5.32)
66.65 (2.62)