IMC-21 Series
Entry-level industrial 10/100BaseT(X) to 100BaseFX media converters
The IMC-21 industrial media converters are entry-level
10/100BaseT(X) to 100BaseFX media converters designed to provide
reliable and stable operation in harsh industrial environments. The
converters are a cost-effective solution that run on either a 12 to 48
VDC power input and can operate reliably in temperatures ranging
from -10 to 60°C. The rugged hardware design ensures that your
Ethernet equipment can withstand demanding industrial conditions.
The IMC-21 converters are easy to mount on a DIN-Rail or in
distribution boxes.
Introduction
Specifications
IMC-21 Series
› Multi-mode or single-mode, with SC or ST fiber connector
› Link Fault Pass-Through (LFP)
› DIP switches to select FDX/HDX/10/100/Auto/Force
Technology
Standards:
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for Flow Control
Interface
RJ45 Ports: 10/100BaseT(X)
Fiber Ports: 100BaseFX (SC/ST connectors)
LED Indicators: Power, 10/100M (TP port), 100M (fiber port), FDX/
COL (fiber port)
DIP Switches: TP port’s 10/100M, Half/Full modes, and Force/Auto
modes, fiber connection’s Full/Half mode, Link Fault Pass-Through
(LFP)
Optical Fiber
100BaseFX
Multi-mode Single-mode
Wavelength
1300 nm 1310 nm
Max. TX
-14 dBm 0 dBm
Min. TX
-20 dBm -5 dBm
RX Sensitivity
-32 dBm -34 dBm
Link Budget
12 dB 29 dB
Typical Distance
5 km
a
4 km
b
40 km
c
Saturation
-6 dBm -3 dBm
a. 50/125 μm, 800 MHz*km fiber optic cable
b. 62.5/125 μm, 500 MHz*km fiber optic cable
c. 9/125 μm, 3.5 PS/(nm*km) fiber optic cable
Physical Characteristics
Housing: Plastic, IP30 protection
Dimensions: 25 x 109 x 97 mm (0.98 x 4.29 x 3.82 in)
Weight: 125 g
Installation: DIN-Rail mounting
Environmental Limits
Operating Temperature: -10 to 60°C (14 to 140°F)
Storage Temperature: -40 to 70°C (-40 to 158°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Power Requirements
Input Voltage: 12 to 48 VDC
Input Current: 150 mA @ 24 VDC
Connection: Removable 3-contact terminal block
Overload Current Protection: 1.1 A
Reverse Polarity Protection: Present
Standards and Certifications
Safety: UL 508
EMC: CE, FCC
EMI: FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS:
EN 61000-4-2 (ESD) Level 3,
EN 61000-4-3 (RS) Level 2,
EN 61000-4-4 (EFT) Level 2,
EN 61000-4-5 (Surge) Level 2,
EN 61000-4-6 (CS) Level 2,
EN 61000-4-8 (PFMF) Level 1
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Green Product: RoHS, CRoHS, WEEE
MTBF (mean time between failures)
Time: 353,000 hrs
Database: MIL-HDBK-217F, GB 25°C