Software Installation
Intellio C218Turbo /PCI User's Manual 3-21
In the “Individual Port Setting” dialog box, you may have two ways to map the
physical ports to COM numbers depending on the “Auto Enumerating COM
number” check box.
Sequential Port Mapping: (Enable “Auto Enumerating COM number”) Specify
the COM number of the first port and subsequent ports are mapped to continuous
COM numbers. For instance, if first port is mapped to COM10, then second port
is mapped to COM11 sequentially.
Non-sequential Port Mapping: (Disable “Auto Enumerating COM number”)
Specify the COM number for individual port. For instance, the second port can
be out of sequence, say COM18, while the first port is mapped to COM10.
In the “Individual Port Setting” dialog box, you may click on [Advanced Settings]
button to tune the advanced features, “UART FIFO” and “Transmission Mode”,
for each port for particular performance requirements.
Note ! You may skip the following settings and go directly to the next step 4,