6-6 Intellio C218Turbo /PCI User's Manual
5. The newly rebuilt kernel could not boot.
The C218Turbo/PCI driver might not be built into the new kernel correctly.
a. Please use the last good kernel backup to boot again. The kernel backup in
SCO UNIX is /unix.moxa while in UNIX SVR4.2 /stand/unix.moxa.
b. Then remove the C218Turbo/PCI driver. Refer to Section “UNIX” of
Chapter “Software Installation” for driver removal.
c. Re-install the C218Turbo/PCI driver once more.
6. When using MOXA port for PPP/SLIP connection, what should the “On
Board Line Discipline” feature be set to?
Set to “Disable”. Otherwise the PPP/SLIP connection will fail.