Moxa Technologies THINKCORE W341 Manual de usuario Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 66
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
1-26
www.moxa.com e-mail: info@moxa.com
1
Serial Device Servers
Selection Guide
NPort 5210 NPort 5230 NPort 5232 NPort 5232I DE-311 DE-211
10M Ethernet
2 (RS-232) 1 RS-232, 1 RS-422/485 2 RS-422/485 2 RS-422/485 1 RS-232/422/485 1 RS-232/422/485
RJ45 Terminal Block Terminal Block Terminal Block DB9 (Female) DB25 (Female)
110 bps to 230.4 Kbps 110 bps to 230.4 Kbps 110 bps to 230.4 Kbps 110 bps to 230.4 Kbps 50 bps to 230.4 Kbps 50 bps to 230.4 Kbps
Parity: None, Even, Odd, Space, Mark; Data Bits: 5, 6, 7, 8; Stop Bit(s): 1, 1.5, 2
XON/XOFF only XON/XOFF only
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, Rtelnet, DNS, SNMP, HTTP, SMTP, SNTP, ARP ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, ARP
NPort Driver Manager for Windows 95/98/ME/NT/2000/XP/2003/Vista
NPort Management Suite for Windows 95/98/ME/NT/2000/
XP/2003
/Vista
Windows 95/98/ME/NT/2000/XP/2003/Vista/XP x64/2003 x64/Vista x64 Real COM driver
Linux real TTY driver Linux2.4.x(x86) / Linux2.6x(x86) / Linux 2.6x(x64)
Unix fixed TTY driver SCO Open Server 5 / SCO Open Server 6 / SCO Open Server 7 / Sun Solaris 10 / QNX 4.25 / QNX 6 / FreeBSD 5.x / FreeBSD 6.x
Web Browser, Serial/Telnet Console, or Windows Utility Serial/Telnet Console, or Windows Utility
Real COM, TCP server, TCP client, UDP, Pair Connection, Reverse Telnet, Disabled Mode
Real COM, TCP server, TCP client, UDP, Pair Connection, Ethernet
Modem
12 to 48 VDC 9 to 30 VDC 12 to 30 VDC
305 mA @ 12V (max.) 347.1 mA @ 12V (max.) 359.6 mA @ 12V (max.) 509.4 mA @ 12V (max.) 300 mA @ 9V (max.) 150 mA @ 12V (max.)
90 × 100.4 × 22 mm
(3.54 × 3.95 × 0.87 in)
67 × 100.4 × 22 mm
(2.64 × 3.95 × 0.87 in)
67 × 100.4 × 22 mm
(2.64 × 3.95 × 0.87 in)
67 × 100.4 × 22 mm
(2.64 × 3.95 × 0.87 in)
67 × 100.4 × 22 mm
(2.64 × 3.95 × 0.87 in)
67 × 100.4 × 22 mm
(2.64 × 3.95 × 0.87 in)
0 to 55°C (32 to 131°F), 5 to 95% RH
-20 to 85°C (-4 to 185°F), 5 to 95% RH
NPort 5210-T NPort 5230-T NPort 5232-T NPort 5232I-T
UL60950-1 UL60950-1 UL60950-1 UL60950-1 UL60950 UL60950
EN60950-1 EN60950-1 EN60950-1 EN60950-1 EN60950 EN60950
Class A Class A Class A Class A Class B Class B
Class A Class A Class A Class A Class B Class B
5 years
Serial Device Servers
Vista de pagina 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 65 66

Comentarios a estos manuales

Sin comentarios