Hardware Installation and IO-IRQ l l Chapter 2
8
Tx: ON
Rx: ON
Jumper Settings for RS-485 Port
There are many combinations of configuration for RS-485. To control the
enable/disable mode of the transmitter and receiver, there are 3 options: "RTS ON",
"REG" and "AUTO" for the transmitter (jumpers for Tx) and 3 options: "RTS OFF",
"REG" and "AUTO" for the receiver (jumpers for Rx) Please decide which you need
and put the jumpers in positions as depicted.
Full Duplex Operation Mode
Tx: RTS ON Tx: REG
Rx: RTS OFF Rx: REG
RTS ON
REG
AUTO
ON
RTS OFF
REG
AUTO
ON
RTS ON
REG
AUTO
ON
RTS OFF
REG
AUTO
ON
RTS ON
REG
AUTO
ON
RTS OFF
REG
AUTO
ON