Intellio C218Turbo User’s ManualA High Performance 8 Port Async Board for ISA busDec. 1999 (3rd Edition)The content of this manual is also available i
1-4 Intellio C218Turbo User's Manual PComm Lite programming library and utilities for Windows NT/95/98 API-232 programming library and utili
Problem Report FormIntellio C218Turbo Customer name: Company: Tel: Fax: Email: Date:1. Moxa Product: C218Turbo Serial Number:___________2. Moxa Dr
IntroductionIntellio C218Turbo User's Manual 1-5Installation GuideThis section gives a brief summary of how to install the C218Turbo under eachs
1-6 Intellio C218Turbo User's Manual
Intellio C218Turbo User's Manual 2-122222222 2 Hardware InstallationHardware InstallationHardware InstallationHardware InstallationThe install
2-2 Intellio C218Turbo User's ManualJP1 (ON: install jumper) (*: default)123456789 IRQON OFF OFF OFF OFF OFF OFF OFF OFF 2OFF ON OFF OFF OFF O
Hardware InstallationIntellio C218Turbo User's Manual 2-3Note ! Make a note of the selected IRQ number and base memoryaddress for software drive
2-4 Intellio C218Turbo User's ManualC218 TurboOpt8A/Opt8B/Opt8SON1 2 3 4 5 6ONASICOpt8C/Opt8DHold one end of the DB62 cable and plug it i
Hardware InstallationIntellio C218Turbo User's Manual 2-5Opt8J/Opt8F/Opt8ZON1 2 3 4 5 6ONASICC218TurboIf you can't make the C218Turb
2-6 Intellio C218Turbo User's ManualRS-422/485 Port Switch of Opt8J1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8DIP ONDIPRS-422 ModeSet the respect
Intellio C218Turbo User's Manual 3-133333333 3 Software InstallationSoftware InstallationSoftware InstallationSoftware InstallationIn this chap
Intellio C218Turbo User’s ManualThe product described in this manual is furnished under a license agreement and may be used only inaccordance with the
3-2 Intellio C218Turbo User's ManualInstalling DriverThe following is the procedure for installing the C218Turbo driver for the firsttime under
Software InstallationIntellio C218Turbo User's Manual 3-35. Select “MOXA Intellio Family Multiport Board” in “Select OEM Option”dialog and then
3-4 Intellio C218Turbo User's ManualSetting” dialog box to change the port COM number mappings.You have to set up all the ports of the board wit
Software InstallationIntellio C218Turbo User's Manual 3-5Note ! You may skip the following settings and go directly to the next step 8 ifyou do
3-6 Intellio C218Turbo User's Manualdata throughput in large data transmission.Classical Mode: It lets MOXA ports behave like generic COM ports.
Software InstallationIntellio C218Turbo User's Manual 3-7Note ! Please double check if all the C218Turbo components: ControlBoard, link cable a
3-8 Intellio C218Turbo User's Manual1. Open [Control Panel], click [Network] icon and select [Adapters] tab.2. Select “MOXA Intellio Family Adap
Software InstallationIntellio C218Turbo User's Manual 3-9In this configuration panel, you may: Click [Property] to enter “Property” dialog box
3-10 Intellio C218Turbo User's ManualWindows 95/98Windows 95/98 supports up to 128 serial ports, from COM1 to COM128. To fullyintegrate the adva
Software InstallationIntellio C218Turbo User's Manual 3-11In this configuration panel, you may: Click on [OK] button to confirm the configurat
MOXA Internet ServicesCustomer’s satisfaction is always our number one concern. To ensure that customers get the full benefit ofour services, Moxa Int
3-12 Intellio C218Turbo User's ManualIn the “Property” dialog, you may click on [Port Setting] button to pop up thefollowing “Individual Port Se
Software InstallationIntellio C218Turbo User's Manual 3-13In the “Individual Port Setting” dialog, you may have two ways to map thephysical port
3-14 Intellio C218Turbo User's ManualIn the “Advanced Settings” dialog, you may customize the driver with thefollowing two features: UART FIFO
Software InstallationIntellio C218Turbo User's Manual 3-156. Restart Windows 95/98 system.Note ! The latest configuration will not take effect
3-16 Intellio C218Turbo User's ManualUpdating DriverOpen [Control Panel] icon, and then [System] icon, and then select [DeviceManager] tab. Then
Software InstallationIntellio C218Turbo User's Manual 3-17UNIXThere are various UNIX operating systems, such as SCO UNIX, UNIX SVR4.2, andSolari
3-18 Intellio C218Turbo User's ManualFollow the instructions prompted to finish the driver installationCopyright (C) 1999 Moxa Technologies Co.,
Software InstallationIntellio C218Turbo User's Manual 3-19Step 7. After system rebooted, please run “mxadm” to configure the board andport setti
3-20 Intellio C218Turbo User's ManualMOXA TTY Device Naming ConventionIf the C218Turbo is successfully configured, there will be two tty devices
Software InstallationIntellio C218Turbo User's Manual 3-21Administration Utility “mxadm”You can use the administration utility, mxadm, to change
About This ManualThis manual is composed of six Chapters and one Appendix. This manual is written for installer, systemadministrator and software prog
3-22 Intellio C218Turbo User's ManualIn the “Basic Configuration” dialog, you should first press Enter in board typefield to select board type,
Software InstallationIntellio C218Turbo User's Manual 3-23In some cases, you may need to modify the “getty default” file as well. Forexample, in
3-24 Intellio C218Turbo User's ManualBaud Rate MappingThis advanced feature is set to “High Band” by default, indicating that the baudrate 50, B
Software InstallationIntellio C218Turbo User's Manual 3-25FeatureIn “Port Feature Settings” sub-dialog, port feature [Terminal] is the only choi
3-26 Intellio C218Turbo User's ManualPerformance TuningThe utility let you tune the favored response time for those ports with Resp = Normor Slo
Software InstallationIntellio C218Turbo User's Manual 3-27However, before the board reset is issued, user must make sure that1. All enabled port
3-28 Intellio C218Turbo User's ManualChecking Board Initialization StatusWhen the system starts up and enters into the multiuser mode, you shoul
Software InstallationIntellio C218Turbo User's Manual 3-29DOSWith over ten years of professional expertise in serial communications, Moxaprovide
3-30 Intellio C218Turbo User's ManualAfter installation is complete, you will be prompted to proceed running setupprogram. It is strongly recomm
Software InstallationIntellio C218Turbo User's Manual 3-312. First, press Enter on the board type field to specify the board type, C218Turbo.3.
Table of ContentsIntroduction ... 1-1Overview ...
3-32 Intellio C218Turbo User's ManualLegendBoard Type: Choose the board type, C218Turbo.Ports: The number of ports for C218Turbo, which is 8.Por
Software InstallationIntellio C218Turbo User's Manual 3-33Legend: Some noticeable fields and functions are explained below.On board TxD buf: The
3-34 Intellio C218Turbo User's Manual5. To setup more boards, please follow the same instructions 2 to 4 describedabove. The maximum supported
Software InstallationIntellio C218Turbo User's Manual 3-35If something went wrong, for instance, the board does not match the configuration orth
3-36 Intellio C218Turbo User's Manual
Intellio C218Turbo User's Manual 4-144444444 4 Serial Programming ToolsSerial Programming ToolsSerial Programming ToolsSerial Programming Tools
4-2 Intellio C218Turbo User's ManualPComm Programming LibraryThe serial communication library is to assist users to develop programs for serialc
Serial Programming ToolsIntellio C218Turbo User's Manual 4-3Diagnostic (for MOXA boards only)A convenient diagnostic program provides internal a
4-4 Intellio C218Turbo User's ManualMonitor (for MOXA boards under Windows NT Only)A useful port status monitoring program allows you to watch t
Serial Programming ToolsIntellio C218Turbo User's Manual 4-5Terminal EmulatorThe Terminal Emulator features multi-windows and supports terminal
PComm Programming Library... 4-2Utilities...
4-6 Intellio C218Turbo User's ManualUNIXProgramming the MOXA PortsThe system calls that apply to standard tty port can also be applied to MOXA p
Serial Programming ToolsIntellio C218Turbo User's Manual 4-7Syntax for SCO UNIX/XENIX#define MIBUFED 0x401int count; /* number of bytes queued i
4-8 Intellio C218Turbo User's Manualioc.ic_dp = (char *)&count;ioctl(moxa_fd, I_STR, &ioc);Note: See MIBUFED for influence of STREAMS dr
Serial Programming ToolsIntellio C218Turbo User's Manual 4-9Syntax for SCO UNIX/XENIX#define MTCDTR 0x404#define TurnON 1#define TurnOFF 0ioctl(
4-10 Intellio C218Turbo User's ManualSyntax for SCO UNIX/XENIX#define MLOWATER 0x405int lowater; /* low water value of output buffer (default =
Serial Programming ToolsIntellio C218Turbo User's Manual 4-117. MHWFLOWThis function is used to enable/disable hardware flow control. The first
4-12 Intellio C218Turbo User's ManualUtilitiesYou can use the administration utility, mxadm, to monitor port activity and to doterminal emulatio
Serial Programming ToolsIntellio C218Turbo User's Manual 4-13Terminal EmulatorThis utility provides data sending and receiving ability of all tt
4-14 Intellio C218Turbo User's Manual2. Select and enter “Terminal” to enter terminal emulation. Or select and enter“Advanced Transfer Modes” to
Serial Programming ToolsIntellio C218Turbo User's Manual 4-15DOSInstallationAPI-232 Library is the professional serial programming tool for DOS.
Intellio C218Turbo User's Manual 1-111111111 1 IntroductionIntroductionIntroductionIntroductionOverviewIntellio - Intelligent Multiport Serial
4-16 Intellio C218Turbo User's ManualData ScopeThe Data Scope, BIN\SCOPE.EXE, is a suite of utility programs that can help userswith system trou
Serial Programming ToolsIntellio C218Turbo User's Manual 4-17DiagnoseThe Diagnose, BIN\DIAGNOSE.EXE, is a utility that can help users to diagnos
4-18 Intellio C218Turbo User's ManualRS-485 Programming for Opt8JIf you intend to do RS-485 communication with Opt8J, please follow the RS-485pr
Serial Programming ToolsIntellio C218Turbo User's Manual 4-19sio_write(port, buff, 10); /* Write 10 byte characters in "buff".The func
4-20 Intellio C218Turbo User's Manual
Intellio C218Turbo User's Manual 5-155555555 5 Connection Option (Opt8x) and Cable WiringIn serial data communications, the term DTE is for Dat
5-2 Intellio C218Turbo User's ManualThe followings are pin assignments for various connection options:Opt8A/S(DCE, DB25 Female)2RxD3TxD4CTS5RTS6
Connection Option (Opt8x) and Cable WiringIntellio C218Turbo User's Manual 5-3Type 1: To connect C218Turbo to a DTE device.PC COM2 port, Serial
5-4 Intellio C218Turbo User's ManualPC COM2 port, Serial Printer,Terminal, or any DTE DeviceOpt8DOpt8D DTE DeviceDB9 Male DB25 MaleRxD 2 2 TxDTx
Connection Option (Opt8x) and Cable WiringIntellio C218Turbo User's Manual 5-5Modem,or any DCE DeviceOpt8B/CStraight-through CableOpt8B/C DCE De
1-2 Intellio C218Turbo User's ManualSurge/Isolation ProtectionTo prevent the boards from damage caused by lightning or high potential voltage,TV
5-6 Intellio C218Turbo User's ManualType 3: To connect C218Turbo to a DTE with 3-pin wiring.If [Hardware flow control] feature is set to “ON”, u
Connection Option (Opt8x) and Cable WiringIntellio C218Turbo User's Manual 5-7PC COM2 port, Serial Printer,Terminal, or any DTE DeviceOpt8DOpt8D
5-8 Intellio C218Turbo User's ManualPC COM2 port, Serial Printer,Terminal, or any DTE DeviceOpt8B/COpt8B/C DTE DeviceDB25 Male DB25 MaleTxD 2 2
Connection Option (Opt8x) and Cable WiringIntellio C218Turbo User's Manual 5-9RS-422 Cable Wiring for Opt8J/F/ZRS-422 connection boxes designed
5-10 Intellio C218Turbo User's ManualThe followings are operation modes for RS-422:RS-422 Point-to-point RS-422 BroadcastingOpt8J/F/Z RS-422 Dev
Connection Option (Opt8x) and Cable WiringIntellio C218Turbo User's Manual 5-11RS-485 Cable Wiring for Opt8JOne RS-485 connection box designed f
5-12 Intellio C218Turbo User's ManualRS-422/485 Impedance MatchingFor RS-422/485 serial communications, when an electrical signal travels throug
Intellio C218Turbo User's Manual 6-166666666 6 TroubleshootingTroubleshootingTroubleshootingTroubleshootingCommon C218Turbo problems and possib
6-2 Intellio C218Turbo User's Manuale. Your mother board does not have vacant IRQ for the C218Turbo. Makesure the desired IRQ is available and n
TroubleshootingIntellio C218Turbo User's Manual 6-3Windows NTThis section is specific for troubleshooting under Windows NT. For generalproblems
IntroductionIntellio C218Turbo User's Manual 1-3FeaturesThe following is a summary of all the outstanding features of C218Turbo: High speed se
6-4 Intellio C218Turbo User's ManualWindows 95/98This section is specific for troubleshooting under Windows 95/98. For generalproblems and solut
TroubleshootingIntellio C218Turbo User's Manual 6-5UNIXThis section is specific for troubleshooting under UNIX. For general problems andsolution
6-6 Intellio C218Turbo User's ManualThe above error messages imply that the system resources are exhausted. Youshould tune the kernel parameters
TroubleshootingIntellio C218Turbo User's Manual 6-7DOSThis section is specific for troubleshooting under DOS. For general problems andsolutions,
6-8 Intellio C218Turbo User's Manual
Intellio C218Turbo User's Manual A-1AAAAAAAA A Technical ReferenceTechnical ReferenceTechnical ReferenceTechnical ReferenceSpecifications Bus
A-2 Intellio C218Turbo User's ManualC218TurboWindows NT ✓Windows 95/98 ✓SCO UNIX/OpenServer/XENIX ✓UNIX SVR4.2 ✓DOS ✓Linux 2.0.x/2.2.x ✓✓ : Driv
Technical ReferenceIntellio C218Turbo User's Manual A-3DB62 Connector PinoutsThe following lists the pin assignments of the DB62 connector on th
Return ProcedureFor product repair, exchange or refund, you must: Provide evidence of original purchase Fill out the Problem Report Form (PRF) as