6-14
Remote Monitoring Solutions
www.moxa.com
6
Video Networking Solutions >
VPort 351 Series
Video
Video Compression: MJPEG or MPEG4 (ISO/IEC 14496-2)
Video Inputs: 1, BNC connector (1.0 Vpp, 75 ohms)
Video Outputs: 1, loop-through BNC connector
NTSC/PAL: Auto-sensing or manual
Video Resolution and FPS (frames per second):
Video Viewing:
• Adjustable image size and quality
• Timestamp and text overlay
Audio
Audio Inputs: 1 Line-in or MIC-in with 3.5 mm phone jack
Audio Outputs: 1 Line-out with 3.5 mm phone jack
Network
Protocols: TCP, UDP, HTTP, SMTP, FTP, Telnet, NTP, DNS, DHCP,
UPnP, RTP, RTSP, ICMP, IGMPv3, QoS, SNMPv1/v2c/v3, DDNS
Ethernet: 1 10/100BaseT(X) auto negotiating RJ45 port, or 1
100BaseFX fi ber port (Single/multi mode, SC connector)
Optical Fiber:
Serial Port
PTZ Ports: 1, RS-232/422/485 port (terminal block connector), max.
speed of 115.2 Kbps
Console Port: 1 RS-232 RJ45 port
GPIO
Digital Inputs: 2, max. 8 mA
• High: +13 to +30V
• Low: -30 to +3V
Relay Outputs: 2, max. 24 VDC @ 1 A
LED Indicators
STAT: Indicates if the system booted properly or not
PWR1: Power 1
PWR2: Power 2
FAULT: Can be confi gured to correspond to system alarm, power
failure, video loss, or disconnected network
VIDEO: Video input signal active
Specifi cations
NTSC PAL
Size Max. FPS Size Max. FPS
QVGA
320 x 240 30 320 x 288 25
CIF
352 x 240 30 352 x 288 25
VGA
640 x 480 30 640 x 576 25
4CIF
704 x 480 30 704 x 576 25
Full D1
720 x 480 30 720 x 576 25
100BaseFX
Multi-mode Single-mode
Wavelength
1300 nm 1310 nm
Max. TX
-10 dBm 0 dBm
Min. TX
-20 dBm -5 dBm
RX Sensitivity
-32 dBm -34 dBm
Link Budget
12 dB 29 dB
Typical
Distance
5 km
a
4 km
b
40 km
c
Saturation
-6 dBm -3 dBm
a. 50/125 µm, 800 MHz*km fi ber optic cable
b. 62.5/125 µm, 500 MHz*km fi ber optic cable
c. 9/125 µm single-mode fi ber optic cable
AUDIO TEST: Audio input signal in test mode
PTZ: PTZ control signal active
Power Requirements
Input Voltage: 2 12/24 VDC or 24 VAC inputs for redundancy
Power Consumption: Max. 8 W
Physical Characteristics
Housing: Metal, IP30 protection
Dimensions: 52.98 x 135 x 105 mm (2.09 x 5.31 x 4.13 in)
Weight: 960 g
Installation: DIN-Rail mounting, wall mounting (with optional kit)
Alarms
Pre/Post Alarm: 9 MB memory for video recordings
Video Motion Detection: Includes sensitivity tuning
Video Loss: Video loss alarm
Scheduling: Daily repeat timing schedule
Imaging: JPEG snapshots for pre/trigger/post alarm images
Email/FTP Messaging: Automatic transfer of stored images via
email or FTP with event-triggered actions
Custom Alarms: HTTP event servers for setting customized alarm
actions
PAN/TILT/ZOOM
PTZ Camera Control: Via RS-232/422/485 PTZ port
PTZ Control Functions: PAN, TILT, ZOOM, FOCUS, moving speed,
preset position (max. 25 positions), and 10 custom commands
PTZ Function Updates: Driver upload supported
Supported Device Protocols: Pelco D, Pelco P, Dynacolor
DynaDome, Custom Camera
Transparent PTZ Control: Control PTZ cameras with legacy PTZ
control panel or keyboard connected to a PC or VPort decoder
Security
Password: User level password protection
Filtering: By IP address
Environmental Limits
Operating Temperature:
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Regulatory Approvals
Safety: UL508
EMS:
EN61000-4-2 (ESD), level 2
EN61000-4-3 (RS), level 3
EN61000-4-4 (EFT), level 3
EN61000-4-5 (Surge), level 3
EN61000-4-6 (CS), level 3
EN61000-4-12 (Oscillatory wave immunity), level 3
EMI: FCC Part 15, CISPR (EN55022) class A
Hazardous Location: UL/cUL Class I, Division 2, Groups A, B, C and
D; ATEX Class I, Zone 2, Ex nC IIC
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Note: Please check Moxa’s website for the most up-to-date certifi cation status.
MTBF (meantime between failures)
Time: 272,000 hrs
Database: MIL-HDBK-217F, GB 25°C
Vista de pagina 13